Scientific instruments are tools for precision measurement, and their precision and reliability must be an order of magnitude higher than the object being measured. Therefore, although there are not as many components as airplanes, the systematic design is also beyond imagination. The chromatographic column, as a consumable, is a separation center, just like the heart. High pressure, tightness and flow rate stability are required. And the oven needs to be kept at a constant temperature. To prevent leakage, maintain constant temperature, pressurized flow, every link, can not be slack. For materials, seals, and fluid mechanics, a high foundation is required.
The method for checking whether the instrument leaks: pinch off the external vacuum skin tube, and observe whether the vacuum gauge on the instrument can keep the instrument leak-free for five minutes. If there is air leakage, check whether the sealing ring on each sealing joint and rotating shaft is effective. On the contrary, the instrument is normal to check the vacuum pump and vacuum pipeline.
Ultimate pressure (mbar):10.1-100
Pumping rate (m3/h):0-5
Origin: domestic
Type: water pump
Without vacuum tube, matching vacuum tube size: inner diameter 6mm, outer diameter 12mm
Use characteristics:
● A large suction pump improved on the basis of the SHB-B type. · Five taps can be used individually or in parallel.
● With five-way pipe (optional) after parallel pumping large, can meet the needs of large rotary evaporator or reactor. * SHB-B95A: shell stainless steel material (SUS standard), others the same SHB-B95.
Technical parameters:
| Model |
Power W |
Power supply V/Hz |
Flow L/min |
Head m |
Security function |
Chassis material |
Maximum vacuum degree MPa |
Single head pumping capacity L/min |
Number of pumping heads (unit) |
Water tank volume L |
Water tank material |
Overall dimension mm |
Weight kg |
| SHB-B95A |
550 |
1 ~,110V60Hz or 220V50Hz or 220V/60Hz |
100 |
12 |
Reverse flow prevention valve |
304 |
0.098 |
10 |
5 |
57 |
PVC |
450L*350W*820H |
36 |
4. method of use
1) Preparation. Lay the SHB circulating water type multi-purpose vacuum pump flat on the workbench. When it is used for the first time, open the upper cover of the water tank and inject clean cold water (water can also be added through the water drain hose). When the water surface is about to rise to the height below the overflow nozzle behind the water tank, stop adding water, and repeat the startup without adding water. But the longest time to replace the water once a week, such as serious water pollution, high utilization rate, can shorten the time to replace the water, the ultimate goal is to keep the water in the tank clean.
2. Vacuum operation. The pumping sleeve of the equipment to be vacuumized is tightly connected to the pumping nozzle of the circulating water type multi-function vacuum pump, the circulation switch is closed, the power supply is connected, and the power switch is turned on to start the vacuuming operation. The vacuum degree can be observed through the vacuum meter corresponding to the pumping nozzle.
3. When the circulating water multi-use vacuum pump needs continuous operation for a long time, the water temperature in the water tank will rise, affecting the vacuum degree. At this time, the drain hose can be connected to the water source (tap water), and the overflow nozzle is used as the drainage outlet. Properly control the flow of tap water to keep the water temperature in the water tank from rising and stabilize the vacuum degree.
4. When it is necessary to provide cooling circulating water for the reaction device, on the basis of the previous operation in Article 3, connect the water inlet and outlet pipes of the device to be cooled to the circulating water outlet and inlet at the rear of the machine respectively, and turn the circulating water switch to the ON position to realize the supply of circulating cooling water.
Five: accessories: fault and troubleshooting methods, vacuum performance table under different temperature conditions, air extraction system repair instructions
Common Faults and Troubleshooting Methods of SHB Series Circulating Water Multi-function Vacuum Pump
| Serial Number |
Common Faults |
Locate |
Exclusion method |
|
|
No vacuum or inaccurate indication of vacuum gauge |
Insufficient motor speed or low voltage |
Check whether the voltage is stable |
| 2, vacuum bottle, check valve dirt blockage or corrosion |
Clean up the internal dirt or replace the new bottle and new valve core |
||
| 3. Water inlet and filter pipe screen are blocked |
Cleaning, taking out the internal dirt |
||
| 4. Impeller falling off |
Replace the impeller |
||
| 5. Water inlet or air leakage of vacuum gauge |
Shake out the water in the meter memory to make the meter needle return to zero or replace the new meter. |
||
| 6. The vacuum pipeline is blocked or the pipe is cracked |
Clean the pipeline or replace it with a new one. |
||
|
2 |
Motor does not work |
Blow-out of insurance pipe |
Replace new safety tube |
| 2. The running capacitor is broken down |
Replace with a new capacitor equal to the original capacity voltage |
||
| 3. The motor winding is burnt out |
Replace the new motor |
||
| 4. The bearing is seriously worn and stuck |
Replace the new bearing |
||
| 5. Impeller is jammed |
Clean up sundries and correct the impeller position |
||
| 6. The thread end is falsely welded or the line card is loose |
Firthy welding, wire clamping |
||
| 3 |
Excessive heating and noise of the motor |
1. Bearing wear |
Replace the new bearing |
| 2. Wear and deformation of impeller |
Replace with a new impeller |
||
| 3, the voltage is unstable or the voltage is too low |
Check whether the line is overloaded and whether there is low voltage |
||
| 4 |
The water tank is churning |
1. The drainage direction of the filter pipe is incorrect |
Adjust the direction of drainage |
| 2, the water level is too low |
Add water to overflow |
||
| 5 |
Water leakage |
The water tank overflow nozzle is loose or the sealing ring is aged. |
Tighten the water nozzle or replace the sealing ring |
| 2. Broken type of water tank |
Replace water tank |
6. circulating water type multi-use vacuum pump vacuum performance under different temperature conditions:
| Temperature ℃ |
6 |
8 |
10 |
15 |
20 |
25 |
30 |
| Vacuum degree MPa |
~0.099 |
~0.099 |
~0.099 |
~0.099 |
0.097 |
0.096 |
0.095 |
| mmHg |
~750 |
~750 |
~748 |
~746 |
736 |
732 |
724 |
Other Options
| Name |
Product Type |
Pumping rate (m3/h): |
Ultimate pressure (mbar): |
Model |
| Vacuum pump |
Water pump |
0-5、5.1-10、10.1-20 |
5.1-10 |
SHB-IIIG |
| Vacuum pump |
Water pump |
0-5、5.1-10、10.1-20 |
5.1-10 |
SHB-E |
| Vacuum pump |
Water pump |
0-5、5.1-10、10.1-20 |
5.1-10 |
SHB-IIIS |
| Vacuum pump |
Water pump |
0-5、5.1-10、10.1-20 |
5.1-10 |
SHB-IIIA |
| Vacuum pump |
Water pump |
0-5、5.1-10、10.1-20 |
5.1-10 |
SHB-III |
| Vacuum pump |
Water pump |
0-5、5.1-10、10.1-20 |
5.1-10 |
SHB-IIIT |
| Vacuum pump |
Water pump |
0-5、5.1-10、10.1-20 |
5.1-10 |
SHB-IV双A |
| Vacuum pump |
Water pump |
0-5、5.1-10、10.1-20 |
5.1-10 |
SHB-B95 |
| Vacuum pump |
Water pump |
0-5、5.1-10、10.1-20 |
5.1-10 |
SHB-B95A |
| Vacuum pump |
Water pump |
0-5、5.1-10、10.1-20 |
5.1-10 |
SHB-B88 |
| Vacuum pump |
Water pump |
0-5、5.1-10、10.1-20 |
5.1-10 |
SHB-B95T |
| Vacuum pump |
diaphragm pump |
0-5、5.1-10、10.1-20 |
5.1-10 |
MP-201 |
Recommended Products
immediate consultation
CONTACT US
Hangzhou Huichuang Instrument & Equipment Co., Ltd.
Telephone:0571-85804016
Mailbox:hc-yq @163. com
Address: Building 25, 889 Huancheng North Road, Deqing County, Huzhou City, Zhejiang Province
©2023 Hangzhou Huichuang Instrument Equipment Co., Ltd powered by www.300.cn SEO