WGSA-25ML-500ML stainless steel reaction kettle
Autonomous products and other conventional products
Classification:
Stainless steel reaction kettle
Magnetic Stirring Reactor
Key words: experimental instrument
online message
Product Details
Scientific instruments are tools for precision measurement, and their precision and reliability must be an order of magnitude higher than the object being measured. Therefore, although there are not as many components as airplanes, the systematic design is also beyond imagination. The chromatographic column, as a consumable, is a separation center, just like the heart. High pressure, tightness and flow rate stability are required. And the oven needs to be kept at a constant temperature. To prevent leakage, maintain constant temperature, pressurized flow, every link, can not be slack. For materials, seals, and fluid mechanics, a high foundation is required.
The method for checking whether the instrument leaks: pinch off the external vacuum skin tube, and observe whether the vacuum gauge on the instrument can keep the instrument leak-free for five minutes. If there is air leakage, check whether the sealing ring on each sealing joint and rotating shaft is effective. On the contrary, the instrument is normal to check the vacuum pump and vacuum pipeline.
Stainless steel reaction kettle
◆ Material: The kettle body is 316L stainless steel, resistant to working pressure of 6MPa. Working temperature: the kettle has a PTFE inner sleeve below 200 ℃
Remember!No PTFE inner sleeve shall be placed in the kettle below 280 ℃.
◆ Heating method: directly surrounding the reactor, simple and convenient, fast heating, strong usability, with a series of electric fiber furnace or electric ring direct heating temperature control, heating power: 100W-230W. Temperature control accuracy: ± 2 ℃
◆ Valve fittings, interfaces are standard configuration.
The stirring speed of 0-3000RPM can be controlled and the temperature is digital display, the speed accuracy of 1RPM
◆ Plug-in needle type K sensor is selected. The working temperature of the heating jacket is below 380 ℃. Display accuracy is below 2 ℃. Stirring device is standard,
It can be filled with inert gas to protect the reactant from direct contact with air.
◆ Can be inserted into the temperature, pressure, PH value, conductivity sensor, to ensure accurate measurement of relevant data.
◆Stainless steel reaction kettleTechnical Highlight (1): Simplify complicated experiments, and realize diversified series experiments under different environments on the same operation platform or under different temperatures/different pressures in the same environment, 25ML/50ML/100ML/200ML250ML/500ML. Can also be used alone or in parallel, series.
Technical parameters:

Recommended Products
immediate consultation
CONTACT US
Hangzhou Huichuang Instrument & Equipment Co., Ltd.
Telephone:0571-85804016
Mailbox:hc-yq @163. com
Address: Building 25, 889 Huancheng North Road, Deqing County, Huzhou City, Zhejiang Province
©2023 Hangzhou Huichuang Instrument Equipment Co., Ltd powered by www.300.cn SEO